The UDK 159 Distillation & Titration System is the fully automatic and interactive solution for your analyses concerning different applications such as determining ammoniacal nitrogen, protein nitrogen, (Kjeldahl or direct alkaline distillation), nitric nitrogen (after reduction), phenols, volatile fatty acids, cyanides, alcohol content and Devarda nitrogen determination.
The UDK 159 runs automatically, after setting distillation time and sodium hydroxide, water and boric acid addition, the steam generation output from 10 to 100% using the innovative 6'' color touch screen. The high-precision pumps and burette ensure constant accurate dosing of reagents and with the integrated colorimetric titrator (AOAC recommended) you will have reliable results concerning your determinations. Automatic titration vessel cleaning provides significant advantages including reducing maintenance to a minimum.
A 54-program library (30 pre-defined + 24 customizable) covers the needs of any laboratory and the reporting system is comprehensive. The UDK 159 offers powerful archiving features. In compliance with GLP (Good Laboratory Practice), the interfaces enable results to be downloaded to a pen drive or directly to a PC. The .csv format permits operators to use well-known software for extracting reports with maximum flexibility. Full understanding and ease of use are ensured the choice of preferred language. 6 languages are supplied as standard; others are downloadable from VELP. The new UDK 159 incorporates a considerably high-tech level, with the VELP patented steam generator that offers high performance, safety (no pressure inside) and is maintenance-free. Another unique VELP component is the titanium condenser, offering reduced water consumption, ensuring that distillate temperature always remains below the threshold value and providing high resistance to breakage. The unit works with a technopolymer splash head to increase the life expectancy substantially and ensures no maintenance. A technopolymer housing provides high chemical resistance against all the reagents used during the process. The UDK 159 is specifically designed to provide full protection of the user. Continuous monitoring indicates incorrect tube and handle positioning; the cooling water flow detector and reagent level alarms provide a high level of safety. Thanks to an innovative system, sample tubes are inserted without any effort using a lever to displace the tube support and clamping the tube in place securely. Different sizes of test tube are accepted. On-board archive for data storage sample data, input from a balance and output to PC, pen drive and printer, in a common format, via Ethernet, USB and RS232 confirm the versatility of the UDK 159.  |  |  |  |  |  |  |  |  | | UDK 159 | 230 V / 50 - 60 Hz | F30200150 |  |  |  |
|
| |  | | GENERAL FEATURES |  |  | | Structure: | Corrosion-resistant technopolymer |  |  | | Display: | 6” color Touch screen |  |  | | Storage capacity: | up to 100,000 measurements |  |  | | Max burette standard volume: | 25 ml (50 ml optional) |  |  | | Min. burette volume: | 2 µl / step |  |  | | Programmable delayed start for Devarda alloy analysis: | 0 – 99 min |  |  | | Protocol Library: | 54 (30 standard + 24 customizable) |  |  | | Selectable language: | UK, I, E, F, RUS, CN + customizable |  |  | | Reproducibility (RSD): | ≤ 1 % |  |  | | Recovery: | ≥ 99.5 % at nitrogen levels between 1 and 200 mg N |  |  | | Detection limit: | ≥ 0.1 mg N |  |  | | Interfaces: | Ethernet, 2 x USB and RS232 |  |  | | Conformity with Standards: | AOAC, EPA, DIN, ISO, GLP |  |  | | Power: | 2200 W |  |  | | Power supply: | 230 V - 50 / 60 Hz |  |  | | Weight: | 31 kg / 68.3 lb |  |  | | Dimensions (WxHxD): | 385x780x416 mm (15.2x30.7x16.4 in) |  |  | | |  |  | | PERFORMANCES |  |  | | Analysis time: | starting from 4 minutes (titration included) |  |  | | Sodium hydroxide addition: | automatic |  |  | | Dilution water addition: | automatic |  |  | | Boric acid addition: | automatic |  |  | | Sodium hydroxide volume: | 0 - 150 ml |  |  | | Dilution water volume: | 0 - 200 ml |  |  | | Boric acid volume: | 0 - 100 ml |  |  | | Titration vessel washing: | automatic |  |  | | Tube drainage: | automatic |  |  | | Steam flow regulation: | 10 – 100 % |  |  | | Tap water consumption: | from 0.5 l/min at 15 °C - from 1 l/min at 30 °C |  |  |
|  |
Note: Kindly Sign in to be able to view more product details.
|